Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 66
Filter
1.
Korean Journal of Radiology ; : 1409-1421, 2019.
Article in English | WPRIM | ID: wpr-760254

ABSTRACT

OBJECTIVE: To develop a diagnostic model for superficial soft tissue lesions to differentiate epidermal cyst (EC) from other lesions based on ultrasound (US) features. MATERIALS AND METHODS: This retrospective study included 205 patients who had undergone US examinations for superficial soft tissue lesions and subsequent surgical excision. The study population was divided into the derivation set (n = 112) and validation set (n = 93) according to the imaging date. The following US features were analyzed to determine those that could discriminate EC from other lesions: more-than-half-depth involvement of the dermal layer, “submarine sign” (focal projection of the hypoechoic portion to the epidermis), posterior acoustic enhancement, posterior wall enhancement, morphology, shape, echogenicity, vascularity, and perilesional fat change. Using multivariable logistic regression, a diagnostic model was constructed and visualized as a nomogram. The performance of the diagnostic model was assessed by calculating the area under the curve (AUC) of the receiver operating characteristic curve and calibration plot in both the derivation and validation sets. RESULTS: More-than-half-depth involvement of the dermal layer (odds ratio [OR] = 3.35; p = 0.051), “submarine sign” (OR = 12.2; p < 0.001), and morphology (OR = 5.44; p = 0.002) were features that outweighed the others when diagnosing EC. The diagnostic model based on these features showed good discrimination ability in both the derivation set (AUC = 0.888, 95% confidence interval [95% CI] = 0.825–0.950) and validation set (AUC = 0.902, 95% CI = 0.832–0.972). CONCLUSION: More-than-half-depth of involvement of the dermal layer, “submarine sign,” and morphology are relatively better US features than the others for diagnosing EC.


Subject(s)
Humans , Acoustics , Calibration , Discrimination, Psychological , Epidermal Cyst , Logistic Models , Nomograms , Retrospective Studies , ROC Curve , Ultrasonography
2.
Annals of Pediatric Endocrinology & Metabolism ; : 81-87, 2018.
Article in English | WPRIM | ID: wpr-714974

ABSTRACT

PURPOSE: This study aimed to investigate associations of central obesity with sexual maturation and metabolic parameters in Korean girls with precocious puberty. METHODS: This retrospective study evaluated data from 72 girls under 8 years of age with a chief complaint of early breast development. The patients were categorized as central precocious puberty (CPP) subjects or non-CPP subjects based on their gonadotropin-releasing hormone stimulation test results. Visceral fat thickness (VFT) was measured using ultrasonography and defined as the distance from the linea alba to the aorta. Patient anthropometric, metabolic, and hormonal parameters were also evaluated. RESULTS: Increased VFT was correlated with an earlier onset of thelarche among all study subjects (r=-0.307, P=0.034). Overweight CPP subjects showed higher insulin resistance than normal weight CPP subjects. Insulin resistance was not significantly different between overweight and normal weight non-CPP subjects. VFT was not significantly different between CPP and non-CPP subjects (2.22±0.79 cm vs. 2.74±1.47 cm, P=0.169). However, overweight and obese CPP subjects (body mass index percentile>85%) had lower VFT than non-CPP obese subjects. CONCLUSIONS: Central obesity, defined using ultrasonography-measured VFT, might be associated with early pubertal development in Korean girls. However, VFT was not higher in CPP than non-CPP patients and was not significantly correlated with insulin resistance. Further longitudinal studies with a larger cohort are needed.


Subject(s)
Female , Humans , Aorta , Breast , Cohort Studies , Gonadotropin-Releasing Hormone , Insulin Resistance , Intra-Abdominal Fat , Longitudinal Studies , Obesity, Abdominal , Overweight , Puberty, Precocious , Retrospective Studies , Sexual Maturation , Ultrasonography
3.
Yonsei Medical Journal ; : 904-907, 2018.
Article in English | WPRIM | ID: wpr-716920

ABSTRACT

Inspissated bile syndrome (IBS) is a relatively rare condition. Many treatment options are available, including medication, surgery, and surgical interventions, such as insertion of cholecystostomy drain, endoscopic retrograde cholangiopancreatography, internal biliary drainage, and percutaneous transhepatic biliary drainage (PTBD). We herein report the first case of IBS that was successfully treated with PTBD in a two-month-old infant in Korea. PTBD was initiated on postnatal day 72. On postnatal day 105, we confirmed complete improvement and successfully removed the catheters. This report suggests that PTBD is a viable and safe treatment option for obstructive jaundice in very young infants.


Subject(s)
Humans , Infant , Bile , Catheters , Cholangiopancreatography, Endoscopic Retrograde , Cholecystostomy , Drainage , Jaundice, Obstructive , Korea
4.
Annals of Pediatric Endocrinology & Metabolism ; : 75-80, 2016.
Article in English | WPRIM | ID: wpr-145161

ABSTRACT

PURPOSE: Abdominal obesity is a fundamental factor underlying the development of metabolic syndrome. Because of radiation exposure and cost, computed tomography or dual-energy X-ray absorptiometry to evaluate abdominal adiposity are not appropriate in children. Authors evaluated whether ultrasound results could be an indicator of insulin resistance and nonalcoholic fatty liver disease (NAFLD). METHODS: We enrolled 73 subjects (aged 6-16 years) who were evaluated abdominal adiposity by ultrasound. Subcutaneous fat thickness was defined as the measurement from the skin-fat interface to the linea alba, and visceral fat thickness (VFT) was defined as the thickness from the linea alba to the aorta. Anthropometric and biochemical metabolic parameters were also collected and compared. The subjects who met 2 criteria, radiologic confirmed fatty liver and alanine aminotransferase >40, were diagnosed with NAFLD. RESULTS: There was a strong positive correlation between VFT and obesity. VFT was highly correlated with the homeostasis model assessment for insulin resistance score (r=0.403, P<0.001). The area under the curve for VFT as a predictor of NAFLD was 0.875 (95% confidence interval [CI], 0.787-0.964). VFT of 34.3 mm was found to be the discriminating cutoff for NAFLD (sensitivity, 84.6%; specificity, 71.2%, respectively). CONCLUSION: Ultrasound could be useful in measuring VFT and assessing abdominal adiposity in children. Moreover, increased VFT might be an appropriate prognostic factor for insulin resistance and NAFLD.


Subject(s)
Child , Humans , Absorptiometry, Photon , Adiposity , Alanine Transaminase , Aorta , Fatty Liver , Homeostasis , Insulin Resistance , Intra-Abdominal Fat , Liver , Non-alcoholic Fatty Liver Disease , Obesity , Obesity, Abdominal , Radiation Exposure , Sensitivity and Specificity , Subcutaneous Fat , Ultrasonography
5.
Annals of Pediatric Endocrinology & Metabolism ; : 75-80, 2016.
Article in English | WPRIM | ID: wpr-145148

ABSTRACT

PURPOSE: Abdominal obesity is a fundamental factor underlying the development of metabolic syndrome. Because of radiation exposure and cost, computed tomography or dual-energy X-ray absorptiometry to evaluate abdominal adiposity are not appropriate in children. Authors evaluated whether ultrasound results could be an indicator of insulin resistance and nonalcoholic fatty liver disease (NAFLD). METHODS: We enrolled 73 subjects (aged 6-16 years) who were evaluated abdominal adiposity by ultrasound. Subcutaneous fat thickness was defined as the measurement from the skin-fat interface to the linea alba, and visceral fat thickness (VFT) was defined as the thickness from the linea alba to the aorta. Anthropometric and biochemical metabolic parameters were also collected and compared. The subjects who met 2 criteria, radiologic confirmed fatty liver and alanine aminotransferase >40, were diagnosed with NAFLD. RESULTS: There was a strong positive correlation between VFT and obesity. VFT was highly correlated with the homeostasis model assessment for insulin resistance score (r=0.403, P<0.001). The area under the curve for VFT as a predictor of NAFLD was 0.875 (95% confidence interval [CI], 0.787-0.964). VFT of 34.3 mm was found to be the discriminating cutoff for NAFLD (sensitivity, 84.6%; specificity, 71.2%, respectively). CONCLUSION: Ultrasound could be useful in measuring VFT and assessing abdominal adiposity in children. Moreover, increased VFT might be an appropriate prognostic factor for insulin resistance and NAFLD.


Subject(s)
Child , Humans , Absorptiometry, Photon , Adiposity , Alanine Transaminase , Aorta , Fatty Liver , Homeostasis , Insulin Resistance , Intra-Abdominal Fat , Liver , Non-alcoholic Fatty Liver Disease , Obesity , Obesity, Abdominal , Radiation Exposure , Sensitivity and Specificity , Subcutaneous Fat , Ultrasonography
6.
Yonsei Medical Journal ; : 1523-1526, 2016.
Article in English | WPRIM | ID: wpr-143151

ABSTRACT

The pulmonary interstitial emphysema (PIE) is a life-threatening illness in premature infants with mechanical ventilation. While most are managed conservatively, decompression would be necessary. Here, we report the first case of PIE treated by percutaneous catheter insertion in an extremely low birth weight (ELBW) infant in Korea. The patient, born with 660 g in 23+2 weeks of gestation, showed PIE in left lower lung on postnatal day 12. Percutaneous catheter insertion was performed on postnatal day 25. The size of PIE decreased, but didn't disappear completely. On postnatal day 42, we exchanged catheter and inserted additional catheter in pleural space. However, sudden desaturation and pneumothorax occurred on postnatal day 44. We changed catheter in pleural space, and pneumothorax and PIE improved. Finally, we successfully removed catheters, and weaned patient out. As in our case, percutaneous catheter insertion would be a useful option for ELBW infants with PIE.


Subject(s)
Humans , Infant , Infant, Newborn , Pregnancy , Catheters , Catheters, Indwelling , Decompression , Emphysema , Infant, Extremely Low Birth Weight , Infant, Low Birth Weight , Infant, Premature , Korea , Lung , Pneumothorax , Pulmonary Emphysema , Respiration, Artificial
7.
Yonsei Medical Journal ; : 1523-1526, 2016.
Article in English | WPRIM | ID: wpr-143146

ABSTRACT

The pulmonary interstitial emphysema (PIE) is a life-threatening illness in premature infants with mechanical ventilation. While most are managed conservatively, decompression would be necessary. Here, we report the first case of PIE treated by percutaneous catheter insertion in an extremely low birth weight (ELBW) infant in Korea. The patient, born with 660 g in 23+2 weeks of gestation, showed PIE in left lower lung on postnatal day 12. Percutaneous catheter insertion was performed on postnatal day 25. The size of PIE decreased, but didn't disappear completely. On postnatal day 42, we exchanged catheter and inserted additional catheter in pleural space. However, sudden desaturation and pneumothorax occurred on postnatal day 44. We changed catheter in pleural space, and pneumothorax and PIE improved. Finally, we successfully removed catheters, and weaned patient out. As in our case, percutaneous catheter insertion would be a useful option for ELBW infants with PIE.


Subject(s)
Humans , Infant , Infant, Newborn , Pregnancy , Catheters , Catheters, Indwelling , Decompression , Emphysema , Infant, Extremely Low Birth Weight , Infant, Low Birth Weight , Infant, Premature , Korea , Lung , Pneumothorax , Pulmonary Emphysema , Respiration, Artificial
8.
Korean Journal of Radiology ; : 903-911, 2016.
Article in English | WPRIM | ID: wpr-115663

ABSTRACT

OBJECTIVE: To investigate the interobserver and test-retest reproducibility of T1ρ and T2 measurements of lumbar intervertebral discs using 3T magnetic resonance imaging (MRI). MATERIALS AND METHODS: This study included a total of 51 volunteers (female, 26; male, 25; mean age, 54 ± 16.3 years) who underwent lumbar spine MRI with a 3.0 T scanner. Amongst these subjects, 40 underwent repeat T1ρ and T2 measurement acquisitions with identical image protocol. Two observers independently performed the region of interest measurements in the nuclei pulposi of the discs from L1–2 through L5–S1 levels. Statistical analysis was performed using intraclass correlation coefficient (ICC) with a two-way random model of absolute agreement. Comparison of the ICC values was done after acquisition of ICC values using Z test. Statistical significance was defined as p value < 0.05. RESULTS: The ICCs of interobserver reproducibility were 0.951 and 0.672 for T1ρ and T2 mapping, respectively. The ICCs of test-retest reproducibility (40 subjects) for T1ρ and T2 measurements were 0.922 and 0.617 for observer A and 0.914 and 0.628 for observer B, respectively. In the comparison of the aforementioned ICCs, ICCs of interobserver and test-retest reproducibility for T1ρ mapping were significantly higher than T2 mapping (p < 0.001). CONCLUSION: The interobserver and test-retest reproducibility of T1ρ mapping were significantly higher than those of T2 mapping for the quantitative assessment of nuclei pulposi of lumbar intervertebral discs.


Subject(s)
Humans , Male , Intervertebral Disc Degeneration , Intervertebral Disc , Magnetic Resonance Imaging , Spine , Volunteers
9.
Korean Journal of Radiology ; : 1086-1095, 2015.
Article in English | WPRIM | ID: wpr-163294

ABSTRACT

OBJECTIVE: To assess whether multi-echo Dixon magnetic resonance (MR) imaging with simultaneous T2* estimation and correction yields more accurate fat-signal fraction (FF) measurement of the lumbar paravertebral muscles, in comparison with non-T2*-corrected two-echo Dixon or T2*-corrected three-echo Dixon, using the FF measurements from single-voxel MR spectroscopy as the reference standard. MATERIALS AND METHODS: Sixty patients with low back pain underwent MR imaging with a 1.5T scanner. FF mapping images automatically obtained using T2*-corrected Dixon technique with two (non-T2*-corrected), three, and six echoes, were compared with images from single-voxel MR spectroscopy at the paravertebral muscles on levels L4 through L5. FFs were measured directly by two radiologists, who independently drew the region of interest on the mapping images from the three sequences. RESULTS: A total of 117 spectroscopic measurements were performed either bilaterally (57 of 60 subjects) or unilaterally (3 of 60 subjects). The mean spectroscopic FF was 14.3 +/- 11.7% (range, 1.9-63.7%). Interobserver agreement was excellent between the two radiologists. Lin's concordance correlation between the spectroscopic findings and all the imaging-based FFs were statistically significant (p < 0.001). FFs obtained from the T2*-corrected six-echo Dixon sequences showed a significantly better concordance with the spectroscopic data, with its concordance correlation coefficient being 0.99 and 0.98 (p < 0.001), as compared with two- or three-echo methods. CONCLUSION: T2*-corrected six-echo Dixon sequence would be a better option than two- or three-echo methods for noninvasive quantification of lumbar muscle fat quantification.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Image Processing, Computer-Assisted , Low Back Pain/diagnostic imaging , Magnetic Resonance Imaging/instrumentation , Muscles/diagnostic imaging , Spinal Cord
10.
Korean Journal of Radiology ; : 1303-1312, 2015.
Article in English | WPRIM | ID: wpr-172975

ABSTRACT

OBJECTIVE: To assess the performance of diffusion tensor imaging (DTI) for the diagnosis of cervical spondylotic myelopathy (CSM) in patients with deformed spinal cord but otherwise unremarkable conventional magnetic resonance imaging (MRI) findings. MATERIALS AND METHODS: A total of 33 patients who underwent MRI of the cervical spine including DTI using two-dimensional single-shot interleaved multi-section inner volume diffusion-weighted echo-planar imaging and whose spinal cords were deformed but showed no signal changes on conventional MRI were the subjects of this study. Mean diffusivity (MD), longitudinal diffusivity (LD), radial diffusivity (RD), and fractional anisotropy (FA) were measured at the most stenotic level. The calculated performance of MD, FA, MD∩FA (considered positive when both the MD and FA results were positive), LD∩FA (considered positive when both the LD and FA results were positive), and RD∩FA (considered positive when both the RD and FA results were positive) in diagnosing CSM were compared with each other based on the estimated cut-off values of MD, LD, RD, and FA from receiver operating characteristic curve analysis with the clinical diagnosis of CSM from medical records as the reference standard. RESULTS: The MD, LD, and RD cut-off values were 1.079 × 10⁻³, 1.719 × 10⁻³, and 0.749 × 10⁻³ mm²/sec, respectively, and that of FA was 0.475. Sensitivity, specificity, positive predictive value and negative predictive value were: 100 (4/4), 44.8 (13/29), 20 (4/20), and 100 (13/13) for MD; 100 (4/4), 27.6 (8/29), 16 (4/25), and 100 (8/8) for FA; 100 (4/4), 58.6 (17/29), 25 (4/16), and 100 (17/17) for MD∩FA; 100 (4/4), 68.9 (20/29), 30.8 (4/13), and 100 (20/20) for LD∩FA; and 75 (3/4), 68.9 (20/29), 25 (3/12), and 95.2 (20/21) for RD∩FA in percentage value. Diagnostic performance comparisons revealed significant differences only in specificity between FA and MD∩FA (p = 0.003), FA and LD∩FA (p < 0.001), FA and RD∩FA (p < 0.001), MD and LD∩FA (p = 0.024) and MD and RD∩FA (p = 0.024). CONCLUSION: Fractional anisotropy combined with MD, RD, or LD is expected to be more useful than FA and MD for diagnosing CSM in patients who show deformed spinal cords without signal changes on MRI.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Cervical Vertebrae , Diffusion Tensor Imaging , Echo-Planar Imaging , ROC Curve , Sensitivity and Specificity , Severity of Illness Index , Spinal Cord Compression/diagnosis , Spinal Cord Diseases/diagnosis
11.
Ultrasonography ; : 267-274, 2014.
Article in English | WPRIM | ID: wpr-731126

ABSTRACT

PURPOSE: To describe the ultrasonographic (US) findings of type IIIa biliary atresia. METHODS: We retrospectively reviewed a medical database of patients pathologically confirmed to have biliary atresia, Kasai type IIIa, between January 2002 and May 2013 (n=18). We evaluated US findings including the visible common bile duct (CBD), triangular cord thickness, gallbladder size and shape, and subcapsular flow on color Doppler US; laboratory data; and pathological hepatic fibrosis grades. We divided them into two groups-those with visible (group A) and invisible (group B) CBD on US-and compared all parameters between the two groups. RESULTS: CBD was visible on US in five cases (27.8%; group A) and invisible in 13 cases (72.2%; group B). US was performed at an earlier age in group A than in group B (median, 27 days vs. 60 days; P=0.027) with the maximal age of 51 days. A comparison of the US findings revealed that the triangular cord thickness was smaller (4.1 mm vs. 4.9 mm; P=0.004) and the gallbladder length was larger (20.0 mm vs. 11.7 mm; P=0.021) in group A. The gallbladder shape did not differ between the two groups, and the subcapsular flow was positive in all cases of both groups. There was no significant difference in the laboratory data between the two groups. Upon pathological analysis, group A showed low-grade and group B showed low- to high-grade hepatic fibrosis. CONCLUSION: When CBD is visible on US in patients diagnosed with type IIIa biliary atresia, other US features could have a false negative status. A subcapsular flow on the color Doppler US would be noted in the type IIIa biliary atresia patients.


Subject(s)
Humans , Biliary Atresia , Common Bile Duct , Fibrosis , Gallbladder , Retrospective Studies , Ultrasonography
12.
Korean Journal of Radiology ; : 781-791, 2014.
Article in English | WPRIM | ID: wpr-228628

ABSTRACT

OBJECTIVE: To assess the feasibility of T2*-corrected fat-signal fraction (FF) map by using the three-echo volume interpolated breath-hold gradient echo (VIBE) Dixon sequence to differentiate between malignant marrow-replacing lesions and benign red marrow deposition of vertebrae. MATERIALS AND METHODS: We assessed 32 lesions from 32 patients who underwent magnetic resonance imaging after being referred for assessment of a known or possible vertebral marrow abnormality. The lesions were divided into 21 malignant marrow-replacing lesions and 11 benign red marrow depositions. Three sequences for the parameter measurements were obtained by using a 1.5-T MR imaging scanner as follows: three-echo VIBE Dixon sequence for FF; conventional T1-weighted imaging for the lesion-disc ratio (LDR); pre- and post-gadolinium enhanced fat-suppressed T1-weighted images for the contrast-enhancement ratio (CER). A region of interest was drawn for each lesion for parameter measurements. The areas under the curve (AUC) of the parameters and their sensitivities and specificities at the most ideal cutoff values from receiver operating characteristic curve analysis were obtained. AUC, sensitivity, and specificity were respectively compared between FF and CER. RESULTS: The AUCs of FF, LDR, and CER were 0.96, 0.80, and 0.72, respectively. In the comparison of diagnostic performance between the FF and CER, the FF showed a significantly larger AUC as compared to the CER (p = 0.030), although the difference of sensitivity (p = 0.157) and specificity (p = 0.157) were not significant. CONCLUSION: Fat-signal fraction measurement using T2*-corrected three-echo VIBE Dixon sequence is feasible and has a more accurate diagnostic performance, than the CER, in distinguishing benign red marrow deposition from malignant bone marrow-replacing lesions.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Area Under Curve , Bone Marrow Cells/cytology , Bone Marrow Transplantation , Contrast Media , Diagnosis, Differential , Magnetic Resonance Imaging , ROC Curve , Sensitivity and Specificity , Signal-To-Noise Ratio , Spinal Diseases/diagnosis
13.
Allergy, Asthma & Immunology Research ; : 179-182, 2014.
Article in English | WPRIM | ID: wpr-19421

ABSTRACT

Eosinophilic fasciitis is a rare disease characterized by diffuse fasciitis with peripheral eosinophilia and progressive induration and thickening of the skin and soft tissues. We report a 19-year-old female who presented with pitting edema in both lower extremities. She had a history of excessive physical activity before her symptoms developed. Physical examination revealed 2+ pitting edema in both lower legs. She complained of mild pain in both knee joints and feet, with no tenderness or heating sensations. Laboratory results were unremarkable except for severe eosinophilia. Parasite infection, venous thrombosis, and cardiac and renal problems were excluded. A magnetic resonance imaging study of both lower extremities revealed increased signal intensity in the subcutaneous lesions, consistent with superficial inflammation of the fascia. Mixed perivenular lymphoplasmacytic and eosinophilic infiltration in the subcutaneous lesion were observed on biopsy. The patient was treated with corticosteroids, resulting in remarkable improvement in both edema and eosinophilia.


Subject(s)
Female , Humans , Young Adult , Adrenal Cortex Hormones , Biopsy , Edema , Eosinophilia , Eosinophils , Fascia , Fasciitis , Foot , Hot Temperature , Inflammation , Knee Joint , Leg , Lower Extremity , Magnetic Resonance Imaging , Motor Activity , Physical Examination , Rare Diseases , Skin
14.
Korean Journal of Radiology ; : 183-193, 2013.
Article in English | WPRIM | ID: wpr-15370

ABSTRACT

OBJECTIVE: To investigate the validity of the 100 kVp setting in CT venography (CTV) in the diagnosis of deep vein thrombosis (DVT), and to evaluate the feasibility of reducing the amount of administered iodine in this setting. MATERIALS AND METHODS: After receiving the contrast medium (CM) of 2.0 mL/kg, 88 patients underwent CTV of the pelvis and lower extremities by using one of four protocols: Group A, 120 kVp setting and 370 mgI/mL CM; group B, 120 kVp and 300 mgI/mL; group C, 100 kVp and 370 mgI/mL; group D, 100 kVp and 300 mgI/mL. The groups were evaluated for venous attenuation, vein-to-muscle contrast-to-noise ratio (CNRVEIN), DVT-to-vein contrast-to-noise ratio (CNRDVT), and subjective degree of venous enhancement and image quality. RESULTS: Venous attenuation and CNRVEIN were significantly higher in group C (144.3 Hounsfield unit [HU] and 11.9), but there was no significant difference between group A (118.0 HU and 8.2) and D (122.4 HU and 7.9). The attenuation value of DVT was not significantly different among the four groups, and group C had a higher absolute CNRDVT than the other groups. The overall diagnostic image quality and venous enhancement were significantly higher in group C, but there was no difference between groups A and D. CONCLUSION: The 100 kVp setting in CTV substantially help improve venous enhancement and CNRVEIN. Furthermore, it enables to reduce the amount of administered iodine while maintaining venous attenuation, as compared with the 120 kVp setting.


Subject(s)
Female , Humans , Male , Middle Aged , Contrast Media/administration & dosage , Feasibility Studies , Iohexol/administration & dosage , Linear Models , Lower Extremity/blood supply , Phantoms, Imaging , Phlebography/methods , Statistics, Nonparametric , Tomography, X-Ray Computed/methods , Venous Thrombosis/diagnostic imaging
15.
Journal of the Korean Society of Magnetic Resonance in Medicine ; : 110-122, 2013.
Article in English | WPRIM | ID: wpr-114745

ABSTRACT

PURPOSE: To compare the image quality and ligament traceability in ankle images obtained using Volume Isotropic Turbo Spin Echo Acquisition (VISTA) MRI with and without fat suppression. MATERIALS AND METHODS: The signal-to-noise ratios (SNRs) in images from a phantom and from the ankle of a volunteer were compared. Ten ankles from 10 non-symptomatic volunteers were imaged for comparisons of contrast ratio (CR) and ligament traceability. All examinations were performed using VISTA sequences with and without fat suppression on a 3T MRI scanner. The SNRs were obtained from images with subjects and without subjects (noise-only). Contrast ratios from images of the 10 ankles were acquired between fluid and tendon (F-T), F-cartilage (C), F-ligament (L), fat (f)-T, f-C and f-L. Two musculoskeletal radiologists independently scored the traceability of 7 ligaments, in sagittal, axial and coronal images respectively, based on a 4-point scale (1 as not traceable through 4 as clearly traceable). The Wilcoxon signed-rank test was used to compare the CR. Fisher's exact test and Pearson's chi-squared test were used to compare the ligament traceability. RESULTS: The SNRs did not differ significantly between the two sequences except in bone marrow. VISTA SPAIR showed the higher CR only in F-T (p = 0.04), whereas VISTA showed higher CR in f-T (p = 0.005), f-C (p = 0.005) and f-L (p = 0.005). The calcaneofibular ligament traceability with VISTA was superior to that obtained with VISTA SPAIR (p < 0.05) in all planes. CONCLUSION: VISTA showed significant superiority to VISTA SPAIR in tracing CFL due to the superior CR between fat and ligament.


Subject(s)
Animals , Ankle , Bone Marrow , Ligaments , Magnetic Resonance Spectroscopy , Magnetics , Magnets , Signal-To-Noise Ratio , Tendons
16.
Korean Journal of Radiology ; : 602-609, 2012.
Article in English | WPRIM | ID: wpr-228973

ABSTRACT

OBJECTIVE: To determine which mode of ultrasonography (US), among the conventional, spatial compound, and tissue-harmonic methods, exhibits the best performance for the detection of Implanon(R) with respect to generation of posterior acoustic shadowing (PAS). MATERIALS AND METHODS: A total of 21 patients, referred for localization of impalpable Implanon(R), underwent US, using the three modes with default settings (i.e., wide focal zone). Representative transverse images of the rods, according to each mode for all patients, were obtained. The resulting 63 images were reviewed by four observers. The observers provided a confidence score for the presence of PAS, using a five-point scale ranging from 1 (definitely absent) to 5 (definitely present), with scores of 4 or 5 for PAS being considered as detection. The average scores of PAS, obtained from the three different modes for each observer, were compared using one-way repeated measure ANOVA. The detection rates were compared using a weighted least square method. RESULTS: Statistically, the tissue harmonic mode was significantly superior to the other two modes, when comparing the average scores of PAS for all observers (p < 0.00-1). The detection rate was also highest for the tissue harmonic mode (p < 0.001). CONCLUSION: Tissue harmonic mode in uS appears to be the most suitable in detecting subdermal contraceptive implant rods.


Subject(s)
Adult , Female , Humans , Middle Aged , Analysis of Variance , Arm/diagnostic imaging , Contraceptive Agents, Female , Desogestrel , Foreign Bodies/diagnostic imaging , Ultrasonography/methods
17.
Pediatric Allergy and Respiratory Disease ; : 428-432, 2012.
Article in Korean | WPRIM | ID: wpr-227502

ABSTRACT

Congenital bronchoesophageal fistula (BEF), congenital communication between esophagus and bronchus, is a rare malformation. Benign BEF shows only nonspecific symptoms that may delay a correct diagnosis and proper treatment. This is a case of a 3-year-old boy presenting congenital BEF with imperforate anus and atrial septal defect. He had recurrent pneumonia in the right lower lobe since he was 5 months old. A barium swallow examination showed a communicating fistula between the lower esophagus and the right lower lobe bronchus. Computed tomography scan supported to delineate the course of the fistula. He underwent resection surgery of the fistula and lobectomy of the right lower lobe. He recovered without any postoperative complications.


Subject(s)
Child , Humans , Anus, Imperforate , Barium , Bronchi , Esophagus , Fistula , Heart Septal Defects, Atrial , Pneumonia , Postoperative Complications
18.
Journal of the Korean Child Neurology Society ; : 231-239, 2011.
Article in English | WPRIM | ID: wpr-80160

ABSTRACT

PURPOSE: A variation in the circle of Willis is not so common, but the most frequent type is hypoplasia/aplasia of the precommunicating anterior cerebral arteries (A1 segment). We aimed to examine the incidence and the clinical significance of A1 segment hypoplasia/aplasia in neuropediatric patients. METHODS: We retrospectively studied children with A1 segment hypoplasia/aplasia in brain magnetic resonance angiography (MRA) and compared the clinical and radiological aspects between children with A1 segment hypoplasia/aplasia alone and with other variations in the circle of Willis. RESULTS: Among 301 patients, 34 patients (11.3%) had A1 segment hypoplasia/aplasia. They presented neurological symptoms such as chronic headache, dizziness and visual disturbance. Seven (20.6%) had family history of neurological illness. Twenty seven (79.4%) had A1 segment hypoplasia/aplasia only, and seven (20.6%) had another vascular abnormality. Seven (20.6%) showed abnormal brain magnetic resonance angiography (MRI) results, cerebral atrophy being the most frequent (n=5, 14.7%). The incidence of abnormal brain MRI was 11.1% (n=3) in single vascular abnormality and 57.1% (n=4), significantly higher (p-value 0.02) in combined abnormality group. CONCLUSION: Structural alterations in the cerebral vasculature in children have important pathophysiological and clinical implications. Evaluation of variations in the circle of Willis, especially of A1 segment hypoplasia/aplasia using MRA is recommended.


Subject(s)
Child , Humans , Anterior Cerebral Artery , Atrophy , Brain , Circle of Willis , Dizziness , Headache Disorders , Incidence , Magnetic Resonance Angiography , Magnetic Resonance Spectroscopy , Magnetics , Magnets , Retrospective Studies
19.
Korean Journal of Radiology ; : 620-625, 2011.
Article in English | WPRIM | ID: wpr-121833

ABSTRACT

Bone metastasis from a spinal cord astrocytoma has been reported only twice in the English medical literature. It is generally known that bone metastasis is found after the initial diagnosis with/without intervening surgery rather than being found at the time of the diagnosis of astrocytoma. The purpose of this article is to report for the first time a case of concurrent bone metastasis from a spinal cord astrocytoma at the time of diagnosing the spinal cord astrocytoma.


Subject(s)
Humans , Male , Middle Aged , Astrocytoma/diagnosis , Lumbar Vertebrae , Magnetic Resonance Imaging , Spinal Cord Neoplasms/diagnosis , Spinal Neoplasms/diagnosis , Thoracic Vertebrae
20.
Korean Journal of Radiology ; : 358-364, 2011.
Article in English | WPRIM | ID: wpr-104804

ABSTRACT

OBJECTIVE: Clear depiction of the common bile duct is important when evaluating neonatal cholestasis in order to differentiate biliary atresia from other diseases. During MR cholangiopancreatography, the T2-shortening effect of gadolinium can increase the contrast-to-noise ratio (CNR) of the bile duct and enhance its depiction. The purpose of this study was to confirm, by performing a phantom study, the T2-shortening effect of gadolinium, to evaluate the effect of different gadolinium chelates with different gadolinium concentrations and different magnetic field strengths for investigating the optimal combination of these conditions, and for identifying the maximum CNR for the evaluation of the biliary system. MATERIALS AND METHODS: MR imaging using a T2-weighted single-shot fast spin echo sequence and T2 relaxometry was performed with a sponge phantom in a syringe tube. Two kinds of contrast agents (Gd-DTPA and Gd-EOB-DTPA) with different gadolinium concentrations were evaluated with 1.5T and 3T scanners. The signal intensities, the CNRs and the T2 relaxation time were analyzed. RESULTS: The signal intensities significantly decreased as the gadolinium concentrations increased (p < 0.001) with both contrast agents. These signal intensities were higher on a 3T (p < 0.001) scanner. The CNRs were higher on a 1.5T (p < 0.001) scanner and they showed no significant change with different gadolinium concentrations. The T2 relaxation time also showed a negative correlation with the gadolinium concentrations (p < 0.001) and the CNRs showed decrease more with Gd-EOB-DTPA (versus Gd-DTPA; p < 0.001) on a 3T scanner (versus 1.5T; p < 0.001). CONCLUSION: A T2-shortening effect of gadolinium exhibits a negative correlation with the gadolinium concentration for both the signal intensities and the T2 relaxation time. A higher CNR can be obtained with Gd-DTPA on a 1.5T MRI scanner.


Subject(s)
Humans , Analysis of Variance , Biliary Atresia/diagnosis , Cholangiopancreatography, Magnetic Resonance/methods , Cholestasis/diagnosis , Contrast Media/administration & dosage , Diagnosis, Differential , Gadolinium DTPA/administration & dosage , Image Processing, Computer-Assisted , Linear Models , Phantoms, Imaging
SELECTION OF CITATIONS
SEARCH DETAIL